Perfomance Of 50 Kl water Tank Under Is -1893 Response Spectra
Abstract
In this research article, an analytical investigation of 50 kL water tank under the action of IS 1893 response spectra has been analyzed. The tank modelled with three types of bracing system i.e. Basic staging, cross staging, radial staging with varying height from 5m,15m,30m,35m is used. A response spectrum analysis is carried, it is observed that basic staging pattern with varying staging height behaves satisfactory ascompared to radial and cross staging pattern.The response obtained for convective mass is less with increasing height of staging but in all over position the response increases with increase in height of staging.